BATTING CAGE
WINTERIZATION GRAVITY FLOW DRAIN SYSTEM
1.
Turn power off leading to A/R Conveyor System and pitching machines.
2. Place plastic bag over pitching machine, light boxes and coin
boxes, ventilate bottom of bags.
3. Remove fiberglass shroud then disconnect conveyor from hopper
and place in area away from rain, snow, sleet etc...
4. Netting System:
The safest method to protect your net and pipe structure would be
to untie the rope lanyards at every perimeter pole and let the net
hang straight down from the net collar. Another method that would
give you a comfortable degree of safety and saves you the job of
pulling the net back up in the spring is as follows.
a) Tie a piece of net twine to the metal ring in the net, then tie
it off to the horizontal rail.
b) Untie rope lanyards from perimeter vertical pipe, leaving untied
end of rope resting on the canopy net. This will hold the net in
place, yet the single strand of twine would break loose under a
heavy load. Upon opening in the spring you would need to retie the
rope lanyards to the vertical pipes.
5.
Unplug Microprocessor power cord from outlet and remove all processor
cards located in the middle of Microprocessor Box, then place cards
in a safe area.
ELECTRIC POWERED
SUMP PUMP DRAIN SYSTEM
1.
Place plastic bag over all pitching machines, then ventilate the
bottom of each bag.
2. Remove light boxes and place in a covered area away from direct
weather. Cover up any bare wiring and place away from flooding levels.
3. Remove fiberglass shroud then disconnect conveyor from hopper
and place in area away from rain, snow, sleet, etc...
4. Netting System: Refer to #4 of “gravity flow drain system”.
5. Unplug Microprocessor power cord from outlet and remove all processor
cards located in the middle of Microprocessor Box, then place cards
in a safe place.
NOTE:
If you have any questions before winterizing please call ABC’s Customer
Service Department for questions. 1-800-578-2243
or 1-503-390-5714.
|